Mostra i principali dati dell'item

dc.creatorVaritimidis, S. E.en
dc.creatorDimitroulias, A. P.en
dc.creatorKarachalios, T. S.en
dc.creatorDailiana, Z. H.en
dc.creatorMalizos, K. N.en
dc.date.accessioned2015-11-23T10:53:17Z
dc.date.available2015-11-23T10:53:17Z
dc.date.issued2009
dc.identifier10.1080/17453670902804877
dc.identifier.issn1745-3674
dc.identifier.urihttp://hdl.handle.net/11615/34326
dc.description.abstractBackground and purpose Tantalum rod implantation has recently been proposed for treatment of early stages of femoral head osteonecrosis. The purpose of our study was to report the early results of its use in pre- and post-collapse stages of the disease. Methods We studied prospectively 27 patients who underwent tantalum rod implantation for treatment of nontraumatic femoral head osteonecrosis between December 2000 and September 2005. Patients were evaluated radiologically and clinically using the Steinberg classification and the Harris hip score (HHS). Disease stage varied between stages II and IV. Mean follow-up time was 38 (15-71) months. Results 1 patient (1 hip) died 15 months after surgery for reasons unrelated to it. 13 of 26 hips remained at the same radiographic stage, and 13 deteriorated. Mean HHS improved from 49 to 85. 6 patients required conversion to total hip arthroplasty. When the procedure was used for stages III and IV, both radiological outcome and revision rates were worse than for the stage II hips. There was, however, no difference in postoperative HHS between patients at pre- and post-collapse stages at the time of initial evaluation. Survivorship, with revision to THA as the endpoint, was 70% at 6 years. Interpretation The disease process does not appear to be interrupted, but there was a significant improvement in hip function initially in most hips. Tantalum rod implantation is a safe buy-time technique, especially when other joint salvage procedures are not an option. Appropriate patient selection and careful rod insertion are needed for favorable results.en
dc.source.uri<Go to ISI>://WOS:000264347300005
dc.subjectCORE DECOMPRESSIONen
dc.subjectAVASCULAR NECROSISen
dc.subjectSURVIVAL ANALYSISen
dc.subjectSTAGE-Ien
dc.subjectHIPen
dc.subjectMANAGEMENTen
dc.subjectARTHROPLASTYen
dc.subjectOSTEOTOMYen
dc.subjectCOLLAPSEen
dc.subjectTHERAPYen
dc.subjectOrthopedicsen
dc.titleOutcome after tantalum rod implantation for treatment of femoral head osteonecrosisen
dc.typejournalArticleen


Files in questo item

FilesDimensioneFormatoMostra

Nessun files in questo item.

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item