Mostrar el registro sencillo del ítem

dc.creatorLavdas, E.en
dc.creatorVlychou, M.en
dc.creatorZaloni, E.en
dc.creatorVassiou, K.en
dc.creatorTsagkalis, A.en
dc.creatorDailiana, Z.en
dc.creatorFezoulidis, I.en
dc.date.accessioned2015-11-23T10:37:33Z
dc.date.available2015-11-23T10:37:33Z
dc.date.issued2015
dc.identifier10.1007/s00256-015-2232-3
dc.identifier.issn3642348
dc.identifier.urihttp://hdl.handle.net/11615/30215
dc.description.abstractObjectives: To evaluate the ability of proton-density with fat-suppression BLADE (proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction in MR systems from Siemens Healthcare, PDFS BLADE) and turbo inversion recovery magnitude-BLADE (TIRM BLADE) sequences to reduce motion and pulsation artifacts in shoulder magnetic resonance examinations. Materials and methods: Forty-one consecutive patients who had been routinely scanned for shoulder examination participated in the study. The following pairs of sequences with and without BLADE were compared: (a) Oblique coronal proton-density sequence with fat saturation of 25 patients and (b) oblique sagittal T2 TIRM-weighed sequence of 20 patients. Qualitative analysis was performed by two experienced radiologists. Image motion and pulsation artifacts were also evaluated. Results: In oblique coronal PDFS BLADE sequences, motion artifacts have been significantly eliminated, even in five cases of non-diagnostic value with conventional imaging. Similarly, in oblique sagittal T2 TIRM BLADE sequences, image quality has been improved, even in six cases of non-diagnostic value with conventional imaging. Furthermore, flow artifacts have been improved in more than 80% of all the cases. Conclusions: The use of BLADE sequences is recommended in shoulder imaging, especially in uncooperative patients because it effectively eliminates motion and pulsation artifacts. © 2015, ISS.en
dc.sourceSkeletal Radiologyen
dc.source.urihttp://www.scopus.com/inward/record.url?eid=2-s2.0-84942294189&partnerID=40&md5=e228fcf2647baa10ee21f732db9b2a56
dc.subjectMagnetic resonance imagingen
dc.subjectMotion artifactsen
dc.subjectPeriodically rotated overlapping parallel lines with enhanced reconstructionen
dc.subjectPulsation artifactsen
dc.subjectShoulderen
dc.titleElimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imagingen
dc.typejournalArticleen


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)