Mostrar el registro sencillo del ítem

dc.creatorDavid, S.en
dc.creatorGeorgiou, M.en
dc.creatorFysikopoulos, E.en
dc.creatorEfthimiou, N.en
dc.creatorPaipais, T.en
dc.creatorKefalidis, L.en
dc.creatorLoudos, G.en
dc.date.accessioned2015-11-23T10:25:14Z
dc.date.available2015-11-23T10:25:14Z
dc.date.issued2012
dc.identifier10.1109/NSSMIC.2011.6154380
dc.identifier.isbn9781467301183
dc.identifier.issn10957863
dc.identifier.urihttp://hdl.handle.net/11615/26943
dc.description.abstractThe aim of this study is to design and apply a symmetric resistive voltage division matrix to read out the compact silicon photomultiplier array (SPMArray2 by SensL) photodetector for possible applications as gamma or PET probes for localization of cancer tumors. We applied a symmetric resistive voltage division circuit, reducing the 16 voltage outputs, which are provided from SensL's evaluation board, to 4 position signals. We acquired raw images and crystal maps from various pixilated scintillators under 99mTc and 22Na excitation, emitting mainly at 140KeV and 511KeV, respectively. The exact values of the resistors as well as the summing amplifiers used in the summation and division stages are given. Moreover, experimental evaluation in terms of energy and spatial resolution is reported. A clear visualization of the discrete 2mm 2 pixilated CsI:Tl scintillator elements under 140keV excitation - with better than 23% energy resolution - was achieved. Raw images of the crystals maps acquired shown visualization of the discrete 1mm 2 CsI:Na scintillator elements under 511keV irradiation. Under 511keV excitation we achieve an energy resolution of ∼35% for BGO and 18% for CsI:Na pixilated scintillators, respectively. All measurements were carried out at room temperature (∼25°C), without additional cooling. © 2011 IEEE.en
dc.source.urihttp://www.scopus.com/inward/record.url?eid=2-s2.0-84858673421&partnerID=40&md5=3c6494ad7b99f22fa37c33be141bbb06
dc.subjectCancer tumoren
dc.subjectEnergy resolutionsen
dc.subjectEvaluation boarden
dc.subjectExperimental evaluationen
dc.subjectPET probeen
dc.subjectPosition signalsen
dc.subjectRaw imagesen
dc.subjectResistive voltageen
dc.subjectRoom temperatureen
dc.subjectSilicon photomultiplieren
dc.subjectSpatial resolutionen
dc.subjectVoltage outputen
dc.subjectIonizationen
dc.subjectMedical imagingen
dc.subjectNuclear physicsen
dc.subjectScintillationen
dc.subjectScintillation countersen
dc.subjectSodiumen
dc.subjectVisualizationen
dc.subjectElectric breakdownen
dc.titleInitial results on SiPM array based on a symmetric resistive voltage division readouten
dc.typeconferenceItemen


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem