Zur Kurzanzeige

dc.creatorVerbitskaya E., Eremin V., Zabrodskii A., Bogdanov A., Shepelev A., Dehning B., Bartosik M.R., Alexopoulos A., Glaser M., Ravotti F., Sapinski M., Härkönen J., Egorov N., Galkin A.en
dc.date.accessioned2023-01-31T10:32:00Z
dc.date.available2023-01-31T10:32:00Z
dc.date.issued2017
dc.identifier10.1088/1748-0221/12/03/C03036
dc.identifier.issn17480221
dc.identifier.urihttp://hdl.handle.net/11615/80580
dc.description.abstractSilicon detectors were proposed as novel Beam Loss Monitors (BLM) for the control of the radiation environment in the vicinity of the superconductive magnets of the High-Luminosity Large Hadron Collider. The present work is aimed at enhancing the BLM sensitivity and therefore the capability of triggering the beam abort system before a critical radiation load hits the superconductive coils. We report here the results of three in situ irradiation tests of Si detectors carried out at the CERN PS at 1.9-4.2 K. The main experimental result is that all silicon detectors survived irradiation up to 1.22× 1016 p/cm2. The third test, focused on the detailed characterization of the detectors with standard (300 μm) and reduced (100 μm) thicknesses, showed only a marginal difference in the sensitivity of thinned detectors in the entire fluence range and a smaller rate of signal degradation that promotes their use as BLMs. The irradiation campaigns produced new information on radiation damage and carrier transport in Si detectors irradiated at the temperatures of 1.9-4.2 K. The results were encouraging and permitted to initiate the production of the first BLM prototype modules which were installed at the end of the vessel containing the superconductive coil of a LHC magnet immersed in superfluid helium to be able to test the silicon detectors in real operational conditions. © 2017 IOP Publishing Ltd and Sissa Medialab srl.en
dc.language.isoenen
dc.sourceJournal of Instrumentationen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85017168058&doi=10.1088%2f1748-0221%2f12%2f03%2fC03036&partnerID=40&md5=15a77c2c4d5059b2c9fecc9546909954
dc.subjectColliding beam acceleratorsen
dc.subjectIrradiationen
dc.subjectMagnetsen
dc.subjectRadiation damageen
dc.subjectSuperconducting coilsen
dc.subjectSuperfluid heliumen
dc.subjectBeam loss monitorsen
dc.subjectCryogenic detectorsen
dc.subjectLarge Hadron Collideren
dc.subjectOperational conditionsen
dc.subjectProfile monitoren
dc.subjectRadiation environmentsen
dc.subjectRadiation hard detectorsen
dc.subjectSignal degradationen
dc.subjectSilicon detectorsen
dc.subjectInstitute of Physics Publishingen
dc.titleDevelopment of silicon detectors for Beam Loss Monitoring at HL-LHCen
dc.typeconferenceItemen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige