dc.description.abstractObjectives: The implication of haemodynamics in the occurrence of complications after endovascular aneurysm repair (EVAR) has been raised in the literature. Different aortic stent graft configurations may lead to different haemodynamic properties. The current study deals with the post-operative haemodynamic variability between four stent graft systems with different structure, material, and type of fixation. Methods: Computed tomography data of 32 patients were used, equally distributed among the four endograft groups, namely the AFX, Endurant, Excluder, and Nellix. Velocity, wall shear stress (WSS), and helicity statistics were calculated, in regions around the flow division where disturbances are expected. The haemodynamic data were compared between and within the groups. Results: The morphology of AAAs pre-operatively did not vary significantly among the four groups. Before the flow division, lowest velocity was observed in Endurant cases and highest in Nellix cases. Endurant induced the lowest peak WSS and Nellix the highest (p = .03). The helicity levels were low in AFX and Nellix cases and high in Endurant and Excluder cases. After the flow division, the trend in the results was preserved. Nellix induced the highest velocity and WSS, followed closely by Excluder and AFX. There was a significant increase of helicity before and after flow division in AFX (p <0.001, R2 = 0.09) and Nellix (p <0.001) cases. Conclusions: It has been shown that different types of endografts induce variable haemodynamic conditions around the flow division. The parallel limb structure, featured by Nellix, seems to induce favourable flow conditions in terms of velocity and WSS, while helical flow before the flow division is suppressed. High WSS is generally considered to be a desirable flow characteristic in endovascular devices, whereas helicity extremes (very low or high) are potentially a negative sign. Endurant, with the stiffer material and the short neck structure, was associated with the lowest blood velocity and WSS values but preserved high helicity levels. The AFX and Excluder, which include the same material, induced similar haemodynamic conditions. © 2019 European Society for Vascular Surgeryen
dc.language.isoenen
dc.sourceEuropean Journal of Vascular and Endovascular Surgeryen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85070687135&doi=10.1016%2fj.ejvs.2019.04.017&partnerID=40&md5=e4cd831bf8ead250fc968a40ccfb23cd
dc.subjectantihypertensive agenten
dc.subjectantithrombocytic agenten
dc.subjectchromiumen
dc.subjectcobalten
dc.subjecthydroxymethylglutaryl coenzyme A reductase inhibitoren
dc.subjectmacrogolen
dc.subjectnitinolen
dc.subjectpolitefen
dc.subjectpolyesteren
dc.subjectpolypropyleneen
dc.subjectabdominal aortaen
dc.subjectabdominal aortic aneurysmen
dc.subjectaortic bifurcationen
dc.subjectArticleen
dc.subjectblood flow velocityen
dc.subjectclinical articleen
dc.subjectcohort analysisen
dc.subjectcomputational fluid dynamicsen
dc.subjectendovascular aneurysm repairen
dc.subjectheart cycleen
dc.subjecthemodynamicsen
dc.subjecthumanen
dc.subjectiliac arteryen
dc.subjectoptimal drug doseen
dc.subjectpriority journalen
dc.subjectshear stressen
dc.subjectsurface propertyen
dc.subjectx-ray computed tomographyen
dc.subjectadverse eventen
dc.subjectaortographyen
dc.subjectbiological modelen
dc.subjectblood vessel prosthesisen
dc.subjectblood vessel transplantationen
dc.subjectcomparative studyen
dc.subjectcomputed tomographic angiographyen
dc.subjectdevicesen
dc.subjectdiagnostic imagingen
dc.subjectendovascular surgeryen
dc.subjecthemodynamicsen
dc.subjectpathophysiologyen
dc.subjectproceduresen
dc.subjectprosthesis designen
dc.subjectstenten
dc.subjecttreatment outcomeen
dc.subjectAortic Aneurysm, Abdominalen
dc.subjectAortographyen
dc.subjectBlood Flow Velocityen
dc.subjectBlood Vessel Prosthesisen
dc.subjectBlood Vessel Prosthesis Implantationen
dc.subjectComputed Tomography Angiographyen
dc.subjectEndovascular Proceduresen
dc.subjectHemodynamicsen
dc.subjectHumansen
dc.subjectModels, Cardiovascularen
dc.subjectPatient-Specific Modelingen
dc.subjectProsthesis Designen
dc.subjectStentsen
dc.subjectTreatment Outcomeen
dc.subjectW.B. Saunders Ltden
dc.titleEndograft Specific Haemodynamics After Endovascular Aneurysm Repair: Flow Characteristics of Four Stent Graft Systemsen
dc.typejournalArticleen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige