Afficher la notice abrégée

dc.creatorPapaoikonomou K., Emmanouil C., Vasilatou V., Diapouli E., Grigoratos T., Zafirakou A., Kungolos A.en
dc.date.accessioned2023-01-31T09:44:13Z
dc.date.available2023-01-31T09:44:13Z
dc.date.issued2018
dc.identifier10.4209/aaqr.2017.12.0557
dc.identifier.issn16808584
dc.identifier.urihttp://hdl.handle.net/11615/77798
dc.description.abstractProcessing Waste of Electrical and Electronic Equipment (WEEE) causes serious environmental problems, especially when WEEE is processed in uncontrolled conditions. WEEE recycling under controlled conditions consists of the following major steps: disassembly, upgrading and refinement. Disassembly is usually done manually, and, at this stage, certain components (cases, external cables, cathode ray tubes [CRTs], printed circuit boards [PCBs], batteries etc.) are separated. This activity releases coarse and fine particles, which may also contain additional noxious substances, into the atmosphere. The current study determines the concentration of indoor PM10 in a Greek plant for the dismantling and temporary storage of WEEE, based on a short-term sampling campaign. Elemental concentrations in the PM10 have also been determined. Results show that the indoor PM10 concentration in the disassembly area did not exceed the time-weighted average (TWA) for total particles set by Greek legislation or the 8-h TWA for total particles set by the Occupational Safety and Health Administration (OSHA). Nevertheless, these concentrations were higher than those measured in the ambient air of Greek cities. Regarding the measured elements, Zn, As, Br, Pb and Cd were quite enriched in PM10, indicating significant indoor sources. Factor analysis of elements of possible anthropogenic origin showed a clear distinction between cathode ray tubes (CRT) and other possible sources. Finally, the risk assessment for metals of toxicological concern showed a non-negligible lifetime risk for 8-h workers. This is the first report of WEEE indoor air pollution in Greece and its associated origins and effects. © Taiwan Association for Aerosol Research.en
dc.language.isoenen
dc.sourceAerosol and Air Quality Researchen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85054380725&doi=10.4209%2faaqr.2017.12.0557&partnerID=40&md5=988029be4e22b4685c4357fe665c1ea4
dc.subjectCathode ray tubesen
dc.subjectCathode raysen
dc.subjectCathodesen
dc.subjectElectronic Wasteen
dc.subjectFlame retardantsen
dc.subjectIndoor air pollutionen
dc.subjectOccupational risksen
dc.subjectOscillators (electronic)en
dc.subjectParticles (particulate matter)en
dc.subjectRecyclingen
dc.subjectRisk assessmenten
dc.subjectDisassemblyen
dc.subjectElemental compositionsen
dc.subjectElemental concentrationsen
dc.subjectOccupational safety and health administrationsen
dc.subjectPM10en
dc.subjectTime-weighted averagesen
dc.subjectWaste of electrical and electronic equipmentsen
dc.subjectWeee recyclingen
dc.subjectPrinted circuit boardsen
dc.subjectAAGR Aerosol and Air Quality Researchen
dc.titlePM10 and elemental concentrations in a dismantling plant for waste of electrical and electronic equipment in Greeceen
dc.typejournalArticleen


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée