dc.description.abstractThe present study aimed to evaluate the accuracy of a numerical model, quantifying real-time ultrasonographic (RTU) images of pregnant sows, to predict litter size. The time of the test with the least error was also considered. A number of 4165 pregnancies in Farm 1 and 438 in Farm 2 were diagnosed twice, with the quality of the RTU images translated into rated-scale values (RSV1 and RSV2). When a deep neural network (DNN) was trained, the evaluation of the method showed that the prediction of litter size can be performed with little error. Root square mean error (RMSE) for training, validation with data from Farm 1, and testing on the data from Farm 2 were 0.91, 0.97, and 1.05, respectively. Corresponding mean absolute errors (MAE) were 2.27, 2.41, and 2.58. Time appeared to be a critical factor for the accuracy of the model. The smallest MAE was achieved when the RTU was performed at days 20–22. It is concluded that a numerical, RTU imaging model is a prominent predictor of litter size, when a DNN is used. Therefore, early routinely evaluated RTU images of pregnant sows can predict litter size, with machine learning, in an automated manner and provide a useful tool for the efficient management of pregnant sows. © 2022 by the authors.en
dc.language.isoenen
dc.sourceAnimalsen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85136475501&doi=10.3390%2fani12151948&partnerID=40&md5=6997fd6fb7462fc4f155d2c302cbcd9f
dc.subjectadulten
dc.subjectarticleen
dc.subjectartificial neural networken
dc.subjectdeep neural networken
dc.subjectechographyen
dc.subjectfemaleen
dc.subjecthumanen
dc.subjectlitter sizeen
dc.subjectmachine learningen
dc.subjectmean absolute erroren
dc.subjectpredictionen
dc.subjectpregnancyen
dc.subjectquantitative analysisen
dc.subjectreal time echographyen
dc.subjectMDPIen
dc.titleEvaluation of a Numerical, Real-Time Ultrasound Imaging Model for the Prediction of Litter Size in Pregnant Sows, with Machine Learningen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής