Afficher la notice abrégée

dc.creatorKampolis C.F., Mermiri M., Mavrovounis G., Koutsoukou A., Loukeri A.A., Pantazopoulos I.en
dc.date.accessioned2023-01-31T08:29:57Z
dc.date.available2023-01-31T08:29:57Z
dc.date.issued2022
dc.identifier10.1016/j.jcrc.2021.11.010
dc.identifier.issn08839441
dc.identifier.urihttp://hdl.handle.net/11615/74248
dc.description.abstractPurpose: To compare neurally adjusted ventilatory assist (NAVA), proportional assist ventilation (PAV), adaptive support ventilation (ASV) and Smartcare pressure support (Smartcare/PS) with standard pressure support ventilation (PSV) regarding their effectiveness for weaning critically ill adults from invasive mechanical ventilation (IMV). Methods: Electronic databases were searched to identify parallel-group randomized controlled trials (RCTs) comparing NAVA, PAV, ASV, or Smartcare/PS with PSV, in adult patients under IMV through July 28, 2021. Primary outcome was weaning success. Secondary outcomes included weaning time, total MV duration, reintubation or use of non-invasive MV (NIMV) within 48 h after extubation, in-hospital and intensive care unit (ICU) mortality, in-hospital and ICU length of stay (LOS) (PROSPERO registration No:CRD42021270299). Results: Twenty RCTs were finally included. Compared to PSV, NAVA was associated with significantly lower risk for in-hospital and ICU death and lower requirements for post-extubation NIMV. Moreover, PAV showed significant advantage over PSV in terms of weaning rates, MV duration and ICU LOS. No significant differences were found between ASV or Smart care/PS and PSV. Conclusions: Moderate certainty evidence suggest that PAV increases weaning success rates, shortens MV duration and ICU LOS compared to PSV. It is also noteworthy that NAVA seems to improve in-hospital and ICU survival. © 2021 Elsevier Inc.en
dc.language.isoenen
dc.sourceJournal of Critical Careen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85119922622&doi=10.1016%2fj.jcrc.2021.11.010&partnerID=40&md5=b326f8b140c30e52140393af80b1d0ca
dc.subjectadaptive servo ventilationen
dc.subjectadulten
dc.subjectcontrolled studyen
dc.subjectextubationen
dc.subjectfemaleen
dc.subjecthumanen
dc.subjectintensive care uniten
dc.subjectlength of stayen
dc.subjectmaleen
dc.subjectmortalityen
dc.subjectoutcome assessmenten
dc.subjectparallel designen
dc.subjectpressure support ventilationen
dc.subjectproportional assist ventilationen
dc.subjectrandomized controlled trial (topic)en
dc.subjectreviewen
dc.subjectsystematic reviewen
dc.subjectventilator weaningen
dc.subjectartificial ventilationen
dc.subjectinteractive ventilatory supporten
dc.subjectmeta analysisen
dc.subjectpositive end expiratory pressure ventilationen
dc.subjectventilator weaningen
dc.subjectAdulten
dc.subjectHumansen
dc.subjectIntensive Care Unitsen
dc.subjectInteractive Ventilatory Supporten
dc.subjectPositive-Pressure Respirationen
dc.subjectRespiration, Artificialen
dc.subjectVentilator Weaningen
dc.subjectW.B. Saundersen
dc.titleComparison of advanced closed-loop ventilation modes with pressure support ventilation for weaning from mechanical ventilation in adults: A systematic review and meta-analysisen
dc.typeotheren


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée