Εμφάνιση απλής εγγραφής

dc.creatorFigliozzi S., Georgiopoulos G., Pateras K., Sianis A., Previtero M., Tondi L., Petropoulos Ι., Bragato R.M., Papachristidis A., Condorelli G., Takeuchi M.en
dc.date.accessioned2023-01-31T07:37:56Z
dc.date.available2023-01-31T07:37:56Z
dc.date.issued2022
dc.identifier10.1007/s10554-021-02520-9
dc.identifier.issn15695794
dc.identifier.urihttp://hdl.handle.net/11615/71558
dc.description.abstractIncreased sizes and dysfunction of the left atrium have been related to adverse outcomes. 3D-echocardiography is more accurate than 2D-echocardiography in estimating LA volumes and ejection fraction. However, the use of 3DE for LA analysis is limited by the absence of established reference values. We performed a systematic review and meta-analysis to provide reference ranges of LA maximum and minimum volumes indexed for body surface area (LAVi max and LAVi min, respectively), and LA-EF assessed by 3DE in healthy adults. Data search was conducted from inception through September 15, 2021, using the following Medical Subject Heading terms: left atrial/atrium, three-dimensional/3D echocardiography. The study protocol was registered in the PROSPERO database (CRD42021252428). 15 studies including 4,226 healthy adults (51% males) and reporting 3DE values of LAVi max, LAVi min and LA-EF were selected. LAVi max, LAVi min and LA-EF mean and reference values were equal to 25.18 ml/m2 (95% CI 23.10, 27.26), 11.10 ml/m2 (10.01, 12.18) and 55.94% (51.92, 59.96), respectively. No influential studies were identified. Pooled estimates per age group- and sex were also estimated. By meta-regression analyses, we identified variability in LA volumes and LA-EF depending on participants’ age, ethnicity and number of heart cycles at 3D multi-beat acquisition. At individual patient data analysis conducted on 374 subjects, a software effect on LA-EF was shown. This systematic review and meta-analysis provides reference values of LAVi max, LAVi min and LA-EF assessed by 3DE in healthy adults, encouraging 3DE evaluation of the LA evaluation in daily practice. © 2022, The Author(s), under exclusive licence to Springer Nature B.V.en
dc.language.isoenen
dc.sourceInternational Journal of Cardiovascular Imagingen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85122504768&doi=10.1007%2fs10554-021-02520-9&partnerID=40&md5=155a6a3989d458bce62d22f28fb709d5
dc.subjectadulten
dc.subjectarticleen
dc.subjectbody surfaceen
dc.subjectcontrolled studyen
dc.subjectethnicityen
dc.subjectfemaleen
dc.subjectgroups by ageen
dc.subjectheart cycleen
dc.subjectheart ejection fractionen
dc.subjectheart left atriumen
dc.subjecthumanen
dc.subjectmaleen
dc.subjectMedical Subject Headingsen
dc.subjectmeta analysisen
dc.subjectnormal valueen
dc.subjectpatient codingen
dc.subjectsoftwareen
dc.subjectsystematic reviewen
dc.subjectthree dimensional echocardiographyen
dc.subjectSpringer Science and Business Media B.V.en
dc.titleNormal ranges of left atrial volumes and ejection fraction by 3D echocardiography in adults: a systematic review and meta-analysisen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής