dc.description.abstractAims Prior work has demonstrated that magnetic resonance imaging (MRI) strain can separate necrotic/stunned myocardium from healthy myocardium in the left ventricle (LV). We surmised that high-resolution MRI strain, using navigator-echo-triggered DENSE, could differentiate radiofrequency ablated tissue around the pulmonary vein (PV) from tissue that had not been damaged by radiofrequency energy, similarly to navigated 3D myocardial delayed enhancement (3D-MDE). Methods and results A respiratory-navigated 2D-DENSE sequence was developed, providing strain encoding in two spatial directions with 1.2 x 1.0 x 4 mm(3) resolution. It was tested in the LV of infarcted sheep. In four swine, incomplete circumferential lesions were created around the right superior pulmonary vein (RSPV) using ablation catheters, recorded with electro-anatomic mapping, and imaged 1 h later using atrial-diastolic DENSE and 3D-MDE at the left atrium/RSPV junction. DENSE detected ablation gaps (regions with >12% strain) in similar positions to 3D-MDE (2D cross-correlation 0.89 +/- 0.05). Low-strain (<8%) areas were, on average, 33% larger than equivalent MDE regions, so they include both injured and necrotic regions. Optimal DENSE orientation was perpendicular to the PV trunk, with high shear strain in adjacent viable tissue appearing as a sensitive marker of ablation lesions. Conclusions Magnetic resonance imaging strain may be a non-contrast alternative to 3D-MDE in intra-procedural monitoring of atrial ablation lesions.en
dc.sourceEuropaceen
dc.source.uri<Go to ISI>://WOS:000331118400025
dc.subjectMagnetic resonance imaging ablationen
dc.subjectAtrial fibrillationen
dc.subjectPorcine modelen
dc.subjectCHRONIC MYOCARDIAL-INFARCTIONen
dc.subjectPULMONARY VEIN CONTRACTIONen
dc.subjectCATHETERen
dc.subjectABLATIONen
dc.subjectINTRACARDIAC ECHOCARDIOGRAPHYen
dc.subjectSTIMULATED ECHOESen
dc.subjectFIBRILLATIONen
dc.subjectMRIen
dc.subjectTRACKINGen
dc.subjectMOTIONen
dc.subjectHEARTen
dc.subjectCardiac & Cardiovascular Systemsen