Mostra i principali dati dell'item

dc.creatorMouchtouri, V.en
dc.creatorVelonakis, E.en
dc.creatorTsakalof, A.en
dc.creatorKapoula, C.en
dc.creatorGoutziana, G.en
dc.creatorVatopoulos, A.en
dc.creatorKremastinou, J.en
dc.creatorHadjichristodoulou, C.en
dc.date.accessioned2015-11-23T10:39:55Z
dc.date.available2015-11-23T10:39:55Z
dc.date.issued2007
dc.identifier10.1128/aem.02192-06
dc.identifier.issn0099-2240
dc.identifier.urihttp://hdl.handle.net/11615/31143
dc.description.abstractThe Legionella colonization frequency at 385 Greek hotel hot and cold water distribution systems was 20.8%. Legionella contamination was associated with the presence of an oil heater (odds ratio [OR] = 2.04, 95% confidence interval [CI] = 1.12 to 3.70), with the sample temperature (OR = 0.26, 95% CI = 0.1 to 0.5), with seasonal operation (OR = 3.23, 95% CI = 1.52 to 6.87), and with the presence of an independent disinfection system (OR = 0.30, 95% CI = 0.15 to 0.62). The same water temperatures, free-chlorine levels, and pHs differently affect the survival of various Legionella spp.en
dc.sourceApplied and Environmental Microbiologyen
dc.source.uri<Go to ISI>://WOS:000245068900013
dc.subjectPARA-OLYMPIC GAMESen
dc.subjectCOLONIZATIONen
dc.subjectBiotechnology & Applied Microbiologyen
dc.subjectMicrobiologyen
dc.titleRisk factors for contamination of hotel water distribution systems by Legionella speciesen
dc.typejournalArticleen


Files in questo item

FilesDimensioneFormatoMostra

Nessun files in questo item.

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item