Zur Kurzanzeige

dc.creatorMetsios, G. S.en
dc.creatorFlouris, A. D.en
dc.creatorKoutedakis, Y.en
dc.creatorNevill, A.en
dc.date.accessioned2015-11-23T10:39:31Z
dc.date.available2015-11-23T10:39:31Z
dc.date.issued2008
dc.identifier10.1016/j.jsams.2006.12.120
dc.identifier.issn14402440
dc.identifier.urihttp://hdl.handle.net/11615/30973
dc.description.abstractWe assessed validity and reliability of the new 20 m square shuttle run test (SST) for predicting maximal oxygen uptake (over(V, ̇) O2 max) and compared it with its predecessor, the 20 m Multistage Shuttle Run Test (MST). In a repeated-measures randomised-block design, 74 healthy adult males performed the SST, the MST and a treadmill test (TT). To assess reliability, 40 of the total 74 volunteers were randomly-selected to perform the SST and MST twice. Unlike the SST (p > 0.05), mean predicted over(V, ̇) O2 max(predover(V, ̇) O2 max) from the MST was significantly increased from that measured during the TT (p < 0.05). The predover(V, ̇) O2 max from SST and MST correlated with TT over(V, ̇) O2 max at r = 0.95 (p < 0.001) and r = 0.63 (p < 0.001), respectively. Prediction error of SST was -0.3 ± 3.3 ml kg-1 min-1 with a coefficient of variation of ±3.5%, while the equivalent values for MST were 4.2 ± 7.3 ml kg-1 min-1 and ±7.4%. Mean test-retest predover(V, ̇) O2 max did not differ for both SST and MST (p > 0.05), while the corresponding test-retest correlation coefficients were r = 0.85 (p < 0.001) and r = 0.72 (p < 0.001). Reliability errors in 95% limits of agreement were 0.3 ± 4.8 and 0.6 ± 6.8 ml kg-1 min-1 while coefficients of variation were ±5.2% and ±6.8% for the SST and MST, respectively. It is concluded that SST is a more valid proxy than MST for predicting laboratory over(V, ̇) O2 max based on the current procedures, while both tests are sufficiently reliable in healthy male adults. © 2007 Sports Medicine Australia.en
dc.source.urihttp://www.scopus.com/inward/record.url?eid=2-s2.0-39049103337&partnerID=40&md5=ebd1be0d5a66c3e2d6b3183fb2c884c1
dc.subjectAgreementen
dc.subjectField testsen
dc.subjectGold standarden
dc.subjectPredictionen
dc.subjectRepeatabilityen
dc.subject20m multistage shuttle run testen
dc.subject20m square shuttle testen
dc.subjectadulten
dc.subjectarticleen
dc.subjectcomparative studyen
dc.subjectcorrelation coefficienten
dc.subjectcriterion related validityen
dc.subjectexercise testen
dc.subjectforced inspiratory volumeen
dc.subjecthumanen
dc.subjectmaleen
dc.subjectnormal humanen
dc.subjectoxygen consumptionen
dc.subjecttest retest reliabilityen
dc.subjecttreadmillen
dc.subjectExerciseen
dc.subjectExercise Toleranceen
dc.subjectHumansen
dc.subjectPredictive Value of Testsen
dc.titleCriterion-related validity and test-retest reliability of the 20 m Square Shuttle Testen
dc.typejournalArticleen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige