Mostra i principali dati dell'item

dc.creatorComodromos, E. M.en
dc.creatorPapadopoulou, M. C.en
dc.date.accessioned2015-11-23T10:24:51Z
dc.date.available2015-11-23T10:24:51Z
dc.date.issued2012
dc.identifier.isbn9780415683678
dc.identifier.urihttp://hdl.handle.net/11615/26750
dc.description.abstractLarge settlements induced to a multi-store building at the initiation of the construction of a diaphragm wall led to a demand of re-dimensioning the initial retaining measures. To achieve this target a multi-stage numerical analysis was carried out including the simulation of excavation using bentonite slurry and concreting stages. Appropriate pre-supporting measures were defined based on an iterative process in order to meet the demands of acceptable level of settlements. A steel tube curtain was applied to minimize the stress release due to unfavorable pressure differentiation. The instrumentation during construction and the comparison of the numerical prediction with the in situ measurements were quite helpful during the application of the proposed design. © 2012 Taylor & Francis Group.en
dc.source.urihttp://www.scopus.com/inward/record.url?eid=2-s2.0-84867186263&partnerID=40&md5=6616c313da7624cd91d2aa4dc54473e1
dc.subjectAdjacent buildingsen
dc.subjectBentonite slurryen
dc.subjectDiaphragm wallen
dc.subjectDuring constructionen
dc.subjectIn-situ measurementen
dc.subjectIterative processen
dc.subjectMulti-stageen
dc.subjectNumerical predictionsen
dc.subjectRe-dimensioningen
dc.subjectRetaining structureen
dc.subjectSteel tubeen
dc.subjectStress releaseen
dc.subjectTubular steel structuresen
dc.subjectNumerical analysisen
dc.titleInteraction of retaining structure with adjacent building: Multi-stage numerical analysisen
dc.typeconferenceItemen


Files in questo item

FilesDimensioneFormatoMostra

Nessun files in questo item.

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item