Mostrar el registro sencillo del ítem

dc.creatorBabis, G. C.en
dc.creatorBenetos, L. S.en
dc.creatorKarachalios, T.en
dc.creatorSoucacos, P. N.en
dc.date.accessioned2015-11-23T10:23:24Z
dc.date.available2015-11-23T10:23:24Z
dc.date.issued2007
dc.identifier10.1016/j.injury.2006.07.030
dc.identifier.issn0020-1383
dc.identifier.urihttp://hdl.handle.net/11615/26074
dc.description.abstractIntramedullary nailing has become a popular and effective procedure for the treatment of most tibial fractures. However, concerns regarding difficulties with reduction, the use and extent of intramedullary reaming, and hardware failure are probably the only constraints to its widespread use. In this prospective study, we present the clinical and radiographic results of the Orthofix(R) tibial nailing system used in the treatment of tibial shaft fractures. One hundred and fifteen fresh tibial fractures in the same number of patients with a mean age of 37.5 years (17-85 years) were treated with operative stabilisation using the Orthofix(R) tibial nailing system. ALL of the operations took place in a conventional operating theatre, on a simple tranlucent operating table and with manual reduction of the fracture. In the majority of the cases closed reduction and conventional reaming were performed and the mean duration of the operation was 38 min. Fracture heating occurred at 16 weeks (11-30 weeks) and was confirmed both clinically and radiographically. In six cases (two severely comminuted and four segmental fractures) delayed union occurred, however there were no tibial non-unions necessitating re-operation. There were no substantial differences in time to fracture union or in the rate of complications related to minimal open reduction. In addition, there seem to be more benefits than risks in the use of power intramedullary reaming during intramedullary fixation of tibial shaft fractures. In conclusion, most tibial shaft fractures can effectively and safety be treated using this type of locking intramedullary nailing device, with relatively few complications, and with satisfactory long-term clinical results. (C) 2006 Elsevier Ltd. All rights reserved.en
dc.sourceInjury-International Journal of the Care of the Injureden
dc.source.uri<Go to ISI>://WOS:000244125100015
dc.subjecttibial shaft fracturesen
dc.subjectintramedullary nailingen
dc.subjectopen reductionen
dc.subjectpoweren
dc.subjectintramedullary reamingen
dc.subjectPLATE FIXATIONen
dc.subjectAIMING DEVICEen
dc.subjectLONG BONESen
dc.subjectKNEE PAINen
dc.subjectINTRAMEDULLARYen
dc.subjectINFECTIONen
dc.subjectMANAGEMENTen
dc.subjectINSERTIONen
dc.subjectINJURIESen
dc.subjectFEMURen
dc.subjectCritical Care Medicineen
dc.subjectEmergency Medicineen
dc.subjectOrthopedicsen
dc.subjectSurgeryen
dc.titleEight years' clinical experience with the Orthofix (R) tibial nailing system in the treatment of tibial shaft fracturesen
dc.typejournalArticleen


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem