Shotgun metagenomics assessment of the resistome, mobilome, pathogen dynamics and their ecological control modes in full-scale urban wastewater treatment plants
Date
2021Language
en
Sujet
Résumé
The conventional activated sludge (CAS) process has limited capacity to remove pathogenic microorganisms and antibiotic resistance genes (ARGs), compared to membrane bioreactors (MBRs). However, the full extent of pathogenic microbial fraction, resistome (antibiotic and biocide resistance genes, ARGs and BRGs) and mobilome (mobile genetic elements, MGE) of urban wastewater treatment plant (UWTP) influents and effluents remains unknown. Thus, the fate of putative pathogenic bacteria, ARGs and potential co-occurrence patterns with BRGs, MGEs and bacterial-predatory microorganisms was determined in two full-scale UWTPs, a MBR and a CAS system, using shotgun metagenomics. Both UWTPs significantly reduced the BOD5 (99.4–99.9%), COD (97.6–99.4%) and TSS (98.9–99.9%). MBR was more effective in reducing the abundance and diversity of pathogen-containing taxa, with 4 and 30 taxa enriched in MBR and CAS effluents, respectively. MBR treatment favored resistance genes associated with triclosan, whereas CAS effluents contained ARGs associated with antibiotics of clinical importance. Correlations between putative pathogenic bacteria, ARG/BRGs/MGEs and bacterial-predatory microorganisms suggested that: (i) opportunistic pathogens (Clostridia, Nocardia) may acquire ARGs against first-line treatments and (ii) bacteriophages may act as a biogenic mechanism of pathogen removal. These findings reinforce the MBR capacity to retain pathogenic components, hence reducing potential health risks associated with treated wastewater reuse. © 2021 Elsevier B.V.
Collections
Related items
Showing items related by title, author, creator and subject.
-
Inactivation, removal, and regrowth potential of opportunistic pathogens and antimicrobial resistance genes in recycled water systems
Drigo B., Brunetti G., Aleer S.C., Bell J.M., Short M.D., Vasileiadis S., Turnidge J., Monis P., Cunliffe D., Donner E. (2021)With two thirds of the global population living in areas affected by water scarcity, wastewater reuse is actively being implemented or explored by many nations. There is a need to better understand the efficacy of recycled ... -
SARS-CoV-2 wastewater monitoring using a novel PCR-based method rapidly captured the Delta-to-Omicron ΒΑ.1 transition patterns in the absence of conventional surveillance evidence
Chassalevris T., Chaintoutis S.C., Koureas M., Petala M., Moutou E., Beta C., Kyritsi M., Hadjichristodoulou C., Kostoglou M., Karapantsios T., Papadopoulos A., Papaioannou N., Dovas C.I. (2022)Conventional SARS-CoV-2 surveillance based on genotyping of clinical samples is characterized by challenges related to the available sequencing capacity, population sampling methodologies, and is time, labor, and ... -
Analysis and evaluation of the operational status of municipal wastewater treatment plants in the Dodecanese prefecture in Greece
Laspidou, C. S.; Gialis, S. E.; Loukas, A.; Kungolos, A. (2011)Data from municipal and private wastewater treatment plants (WWTP) in the Dodecanese prefecture in Greece was collected via a questionnaire and personal interviews, and was analyzed with respect to the operational status ...