Zur Kurzanzeige

dc.creatorFanariotis M., Tsougos I., Vlychou M., Fezoulidis I., Vassiou K.en
dc.date.accessioned2023-01-31T07:37:36Z
dc.date.available2023-01-31T07:37:36Z
dc.date.issued2018
dc.identifier10.1016/j.crad.2018.06.019
dc.identifier.issn00099260
dc.identifier.urihttp://hdl.handle.net/11615/71453
dc.description.abstractAim: To evaluate the effect of intravenous gadolinium contrast agent on diffusion-weighted sequences and apparent diffusion coefficient (ADC) measurements at 3 T. Materials and methods: Sixty-two biopsy-proven breast lesions were included in this prospective study. Magnetic resonance imaging (MRI) was performed at 3 T, using four echo-planar diffusion-weighted sequences (7,100 ms repetition time, 84 ms echo time) with b-values of 0 and 850, and 0 and 1,000 s/mm2. The first pair of DWI sequences was taken before intravenous contrast medium injection. The second pair of sequences was taken 6.5 minutes after intravenous contrast medium administration (right after the dynamic T1 sequence). A freeform region of interest (ROI) was drawn inside the lesion excluding adjacent normal tissue, necrotic, or cystic components and ADC values were calculated. The paired samples t-test was used to assess differences between ADC measurements before and after intravenous contrast medium administration. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were calculated for each diffusion sequence. Results: Twenty-seven malignant and 35 benign lesions were analysed. Fifty-eight lesions were masses, and four lesions were non-mass-like enhancements (NMLEs). Two of the NMLEs were malignant, and two were benign lesions. The contrast-enhanced ADC measurements were lower than the unenhanced measurements on b=850 and 1,000 s/mm2 (p<0.05). The receiver operating characteristic (ROC) analysis displayed similar area under the curve values between the different diffusion sequences. Conclusion: The injection of intravenous contrast medium reduces ADC values; however, the effect of contrast medium is modest. Sensitivity and specificity are not significantly affected. © 2018 The Royal College of Radiologistsen
dc.language.isoenen
dc.sourceClinical Radiologyen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85050457498&doi=10.1016%2fj.crad.2018.06.019&partnerID=40&md5=c0f79eeb1f13a17664c8815d45cfaf64
dc.subjectcontrast mediumen
dc.subjectgadoliniumen
dc.subjectcontrast mediumen
dc.subjectarea under the curveen
dc.subjectArticleen
dc.subjectbreast carcinomaen
dc.subjectbreast lesionen
dc.subjectcontrast-enhanced ultrasounden
dc.subjectdiagnostic accuracyen
dc.subjectdiffusion weighted imagingen
dc.subjecthumanen
dc.subjectintraductal carcinomaen
dc.subjectlobular carcinomaen
dc.subjectlobular carcinoma in situen
dc.subjectmajor clinical studyen
dc.subjectmeasurementen
dc.subjectpredictive valueen
dc.subjectpriority journalen
dc.subjectprospective studyen
dc.subjectsensitivity and specificityen
dc.subjectbreasten
dc.subjectbreast tumoren
dc.subjectdiagnostic imagingen
dc.subjectfemaleen
dc.subjectintravenous drug administrationen
dc.subjectmicrocirculationen
dc.subjectproceduresen
dc.subjectvascularizationen
dc.subjectBreasten
dc.subjectBreast Neoplasmsen
dc.subjectContrast Mediaen
dc.subjectDiffusion Magnetic Resonance Imagingen
dc.subjectFemaleen
dc.subjectHumansen
dc.subjectInjections, Intravenousen
dc.subjectMicrocirculationen
dc.subjectProspective Studiesen
dc.subjectW.B. Saunders Ltden
dc.titleContrast-enhanced and unenhanced diffusion-weighted imaging of the breast at 3 Ten
dc.typejournalArticleen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige