Εμφάνιση απλής εγγραφής

dc.creatorKanski, M.en
dc.creatorToger, J.en
dc.creatorSteding-Ehrenborg, K.en
dc.creatorXanthis, C.en
dc.creatorBloch, K. M.en
dc.creatorHeiberg, E.en
dc.creatorCarlsson, M.en
dc.creatorArheden, H.en
dc.date.accessioned2015-11-23T10:32:33Z
dc.date.available2015-11-23T10:32:33Z
dc.date.issued2015
dc.identifier10.1186/s12880-015-0061-4
dc.identifier.issn1471-2342
dc.identifier.urihttp://hdl.handle.net/11615/28874
dc.description.abstractBackground: Respiratory gating is often used in 4D-flow acquisition to reduce motion artifacts. However, gating increases scan time. The aim of this study was to investigate if respiratory gating can be excluded from 4D flow acquisitions without affecting quantitative intracardiac parameters. Methods: Eight volunteers underwent CMR at 1.5 T with a 5-channel coil (5ch). Imaging included 2D flow measurements and whole-heart 4D flow with and without respiratory gating (Resp(+), Resp(-)). Stroke volume (SV), particle-trace volumes, kinetic energy, and vortex-ring volume were obtained from 4D flow-data. These parameters were compared between 5ch Resp(+) and 5ch Resp(-). In addition, 20 patients with heart failure were scanned using a 32-channel coil (32ch), and particle-trace volumes were compared to planimetric SV. Paired comparisons were performed using Wilcoxon's test and correlation analysis using Pearson r. Agreement was assessed as bias +/- SD. Results: Stroke volume from 4D flow was lower compared to 2D flow both with and without respiratory gating (5ch Resp(+) 88 +/- 18 vs 97 +/- 24.0, p = 0.001; 5ch Resp(-) 86 +/- 16 vs 97.1 +/- 22.7, p < 0.01). There was a good correlation between Resp(+) and Resp(-) for particle-trace derived volumes (R-2 = 0.82, 0.2 +/- 9.4 ml), mean kinetic energy (R-2 = 0.86, 0.07 +/- 0.21 mJ), peak kinetic energy (R-2 = 0.88, 0.14 +/- 0.77 mJ), and vortex-ring volume (R-2 = 0.70, -2.5 +/- 9.4 ml). Furthermore, good correlation was found between particle-trace volume and planimetric SV in patients for 32ch Resp(-) (R-2 = 0.62, -4.2 +/- 17.6 ml) and in healthy volunteers for 5ch Resp(+) (R-2 = 0.89, -11 +/- 7 ml), and 5ch Resp(-) (R-2 = 0.93, -7.5 +/- 5.4 ml), Average scan duration for Resp(-) was shorter compared to Resp(+) (27 +/- 9 min vs 61 +/- 19 min, p < 0.05). Conclusions: Whole-heart 4D flow can be acquired with preserved quantitative results without respiratory gating, facilitating clinical use.en
dc.source.uri<Go to ISI>://WOS:000356410200001
dc.subjectCardiac MRIen
dc.subject4D flowen
dc.subjectRespiratory gatingen
dc.subjectKinetic energyen
dc.subjectParticleen
dc.subjecttraceen
dc.subjectVortex ring sizeen
dc.subjectCARDIOVASCULAR MAGNETIC-RESONANCEen
dc.subjectVENTRICULAR BLOOD-FLOWen
dc.subjectQUANTIFICATIONen
dc.subjectVISUALIZATIONen
dc.subjectMRIen
dc.subjectACQUISITIONen
dc.subjectVALIDATIONen
dc.subjectPATTERNSen
dc.subject3Den
dc.subjectRadiology, Nuclear Medicine & Medical Imagingen
dc.titleWhole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use: a head-to-head comparisonen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής