Mostra i principali dati dell'item

dc.creatorHantes, M. E.en
dc.creatorKotsovolos, E. S.en
dc.creatorMastrokalos, D. S.en
dc.creatorAmmenwerth, J.en
dc.creatorPaessler, H. H.en
dc.date.accessioned2015-11-23T10:29:53Z
dc.date.available2015-11-23T10:29:53Z
dc.date.issued2005
dc.identifier10.1007/s00167-004-0527-3
dc.identifier.issn0942-2056
dc.identifier.urihttp://hdl.handle.net/11615/28418
dc.description.abstractThe results of a new method for arthroscopic all-inside meniscus repair using a biodegradable cannulated screw (Clearfix meniscal screw) were assessed in a medium-term follow-up prospective study. The Clearfix meniscal screw system consists of delivery cannulae, screw driver, and screw implants. After tear debridement, a screw is located on the driver and passed through the cannula to the insertion site, holding the two sides of the tear together under linear compression. Forty-eight patients (48 repairs) with a mean age of 32.7 years were included in the study. Ligament stabilizing procedures were done in 39 patients (81%) who had anterior cruciate ligament deficient knees. Only longitudinal lesions in the red/red or red/white zone were repaired. Follow-up averaged 19 months, with a range from 12 to 48 months. Patients were evaluated using clinical examination, the "Orthopaedische Arbeitsgemeinschaft Knie (OAK)" knee evaluation scheme and magnetic resonance imaging (MRI). Criteria for clinical success included absence of joint-line tenderness, absence of swelling and a negative McMurray test. Postoperatively, there were no complications directly associated with the device. Twelve of 48 repaired menisci (25%) were considered failures according to the above-mentioned criteria. According to the OAK knee evaluation scheme, 38 patients (79%) had an excellent or good result. MRI, however, showed persisting grade III or IV lesions in 35 patients (73%). Analysis showed that age, length of tear, and simultaneous anterior cruciate ligament reconstruction did not affect the clinical outcome. In contrast, risk factors for failure of meniscus repair are chronicity of injury, location of tear more than 3 mm from the meniscosynovial junction and meniscus side (medial).en
dc.sourceKnee Surgery Sports Traumatology Arthroscopyen
dc.source.uri<Go to ISI>://WOS:000228974000006
dc.subjectmeniscus repairen
dc.subjectabsorbable screwen
dc.subjectClearfixen
dc.subjectCRUCIATE LIGAMENT RECONSTRUCTIONen
dc.subjectKNEE-JOINTen
dc.subject2ND-LOOK ARTHROSCOPYen
dc.subjectLOAD-BEARINGen
dc.subjectFOLLOW-UPen
dc.subjectARROWen
dc.subjectTEARSen
dc.subjectINJURIESen
dc.subjectOUTCOMESen
dc.subjectDEVICESen
dc.subjectOrthopedicsen
dc.subjectSport Sciencesen
dc.subjectSurgeryen
dc.titleArthroscopic meniscal repair with an absorbable screw: results and surgical techniqueen
dc.typejournalArticleen


Files in questo item

FilesDimensioneFormatoMostra

Nessun files in questo item.

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item