Zur Kurzanzeige

dc.creatorFlouris, A. D.en
dc.creatorKoutedakis, Y.en
dc.creatorNevill, A.en
dc.creatorMetsios, G. S.en
dc.creatorTsiotra, G.en
dc.creatorParasiris, Y.en
dc.date.accessioned2015-11-23T10:26:36Z
dc.date.available2015-11-23T10:26:36Z
dc.date.issued2004
dc.identifier10.1016/s1440-2440(04)80009-4
dc.identifier.issn1440-2440
dc.identifier.urihttp://hdl.handle.net/11615/27490
dc.description.abstractThe purpose of this study was to examine the hypothesis that improved prediction of bioenergeties may be achieved when proxies are designed to simulate closely gold standard laboratory protocols. To accomplish this, a modified 'square' variation (SST) of the classical 20m Multistage Shuttle Run Test (MST) was designed aiming to reduce the stopping, turning and side-stepping manoeuvres. Within two weeks, 50 male volunteers (age 21.5+/-1.6, BMI 24.4+/-2.2) randomly underwent three maximal oxygen uptake ( VO2max) assessments using a treadmill test (TT), the SST and MST. To assess SST reproducibility, 10 randomly-selected subjects performed the test twice. Validity results showed that mean predicted VO2max from SST was not significantly different compared to Tr VO2max (p>0.05). In contrast, the equivalent value from MST was significantly higher (p<0.001) than TT. Furthermore, TT VO2max correlated with SST and MST at r=0.88 (p<0.001) and r=0.61 (p<0.05), respectively. The '95% limits of agreement' analysis (LIMAG) for SST and MST indicated a range of error equal to -0.5+/-5.4 and 8.1+/-8.0 (ml.kg(-1)-min(-1)) with a coefficient of variation of 6 and +/-8.2%, respectively. Test-retest results for SST revealed no mean difference in VO2max (p>0.05) and a correlation coefficient of r=0.98 (p<0.001), while LIMAG demonstrated a range of error equal to -0.2+/-2.6 (ml-kg(-1)-min(-1)) with a coefficient of variation of +/-5.6%. It is concluded that, compared to MST, the SST had a higher agreement with TT. The latter may well be explained by the closer simulation in bioenergeties between the two protocols (ie, the continuous nature of SST provides a closer proxy of TT).en
dc.sourceJournal of Science and Medicine in Sporten
dc.source.uri<Go to ISI>://WOS:000223134700009
dc.subjectMAXIMAL OXYGEN-UPTAKEen
dc.subjectASSESSING AGREEMENTen
dc.subjectAEROBIC CAPACITYen
dc.subjectTESTSen
dc.subjectTREADMILLen
dc.subjectEXERCISEen
dc.subjectVALIDITYen
dc.subjectSport Sciencesen
dc.titleEnhancing specificity in proxy-design for the assessment of bioenergeticsen
dc.typejournalArticleen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige