Systematic review of reintervention with fenestrated or branched devices after failed previous endovascular aortic aneurysm repair

Thumbnail
Συγγραφέας
Nana P., Kölbel T., Behrendt C.-A., Kouvelos G., Giannoukas A., Haulon S., Spanos K.
Ημερομηνία
2022
Γλώσσα
en
DOI
10.1016/j.jvs.2022.11.037
Λέξη-κλειδί
Elsevier Inc.
Εμφάνιση Μεταδεδομένων
Επιτομή
Background: A proximal seal extension, after previously failed standard endovascular abdominal aortic aneurysm repair (EVAR), has been described using various endovascular techniques. The aim of the present systematic review was to assess the technical success, 30-day mortality, and mortality and reintervention rates during the available follow-up for patients managed with endovascular methods after failed endovascular repair. Methods: The present systematic review followed the PRISMA (preferred reporting items for systematic reviews and meta-analyses) statement and was preregistered at PROSPERO (no. CRD42022350436). A search of the English literature, via Ovid, using the MEDLINE, EMBASE, and CENTRAL databases, until June 15, 2022, was performed. Observational studies (2000-2022) and case series with at least five patients who had undergone fenestrated/branched EVAR (F/BEVAR) after failed EVAR were considered eligible. Technical success and mortality at 30 days and the mortality and reintervention rates during available follow-up had to have been reported. The Newcastle-Ottawa scale was used to assess the risk of bias. The primary outcome was technical success and mortality at 30 days. Results: The initial search yielded 2558 reports. Ten studies were considered eligible, two of which were prospective. A total of 423 patients had undergone F/BEVAR after failed EVAR. The indication for reintervention was the presence of a type Ia endoleak in 44.9%. Technical success was reported in seven studies, and 319 of 336 interventions were considered successful (94.9%), according to each study's criteria. Of the 423 patients, 10 had died within 30 days (2.4%). Seven patients had presented with spinal cord ischemia (2.4%). Twenty-three acute kidney injury events were reported (6.8%). The mean follow-up was 18 months (range, 1-77 months). During follow-up, 47 deaths were reported (14.8%). Finally, 50 reinterventions of 303 procedures (16.5%) had been performed. Conclusions: According to the available literature, F/BEVAR after failed EVAR can be performed with high technical success and low mortality during the perioperative period. The midterm mortality and reintervention rates were acceptable. However, further data are needed to provide firm conclusions regarding the safety and durability of F/BEVAR after failed EVAR. © 2022 Society for Vascular Surgery
URI
http://hdl.handle.net/11615/76889
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Πλοήγηση

Όλο το DSpaceΚοινότητες & ΣυλλογέςΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιάΑυτή η συλλογήΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιά

Ο λογαριασμός μου

ΣύνδεσηΕγγραφή (MyDSpace)
Πληροφορίες-Επικοινωνία
ΑπόθεσηΣχετικά μεΒοήθειαΕπικοινωνήστε μαζί μας
Επιλογή ΓλώσσαςΌλο το DSpace
EnglishΕλληνικά
htmlmap