Logo
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • English 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
View Item 
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
Institutional repository
All of DSpace
  • Communities & Collections
  • By Issue Date
  • Authors
  • Titles
  • Subjects

Comparison of a non-contact infrared thermometer with a rectal digital thermometer for use in ewes

Thumbnail
Author
Katsoulos P.D., Athanasiou L.V., Karatzia M.A., Valasi I., Boscos C., Karatzias H.
Date
2016
Language
en
DOI
10.1016/j.smallrumres.2016.09.004
Keyword
Elsevier B.V.
Metadata display
Abstract
The aim of this study was to assess the accuracy of measuring body temperature in sheep using a noncontact infrared thermometer on the inguinal area and the eye cornea in comparison with a rectal digital thermometer. The trial for the first comparison was conducted in the milking parlor in 52 ewes in full lactation and 15 dry ewes and for the second one in 51 ewes. The body temperature measured with the noncontact infrared thermometer in the inguinal area, although significantly lower, was strongly linearly correlated with that of the rectal digital one in both ewes in full lactation and dry ewes. In lactating ewes, besides the high precision, the highest accuracy was also recorded and the plotted differences were within clinically insignificant levels. The corneal temperatures were highly correlated but were significantly lower compared to the rectal ones. Due to these differences the cut-off point of 37.9 °C was estimated to be adopted for the detection of the hyperthermic animals when noncontact infrared thermometers are applied to the eye cornea for the measurement of body temperature. In conclusion the inguinal area of the dry ewes and the eye cornea cannot be recommended as appropriate sites for body temperature measurement because the temperatures recorded are biased by external factors. The noncontact infrared thermometer evaluated is sufficiently accurate for the measurement of body temperature in sheep only when applied in the inguinal area of sheep in full lactation. © 2016 Elsevier B.V.
URI
http://hdl.handle.net/11615/74681
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap