• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Deutsch 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Einloggen
Dokumentanzeige 
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.
Gesamter Bestand
  • Bereiche & Sammlungen
  • Erscheinungsdatum
  • Autoren
  • Titeln
  • Schlagworten

Urethrographic examinations: Patient and staff exposures and associated radiobiological risks

Thumbnail
Autor
Alkhorayef M., Sulieman A., Barakat H., Al-Mohammed H.I., Theodorou K., Kappas C., Bradley D.
Datum
2021
Language
en
DOI
10.1016/j.sjbs.2020.08.026
Schlagwort
Elsevier B.V.
Zur Langanzeige
Zusammenfassung
Medical exposure of the general population due to radiological investigations is the foremost source of all artificial ionising radiation. Here, we focus on a particular diagnostic radiological procedure, as only limited data are published with regard to radiation measurements during urethrograpic imaging. Specifically, this work seeks to estimate patient and occupational effective doses during urethrographic procedures at three radiology hospitals. Both staff and patient X-ray exposure levels were calculated in terms of entrance surface air kerma (ESAK), obtained by means of lithium fluoride thermoluminescent dosimeters (TLD-100(LiF:Mg:Cu.P)) for 243 urethrographic examinations. Patient radiation effective doses per procedure were estimated using conversion factors obtained from the use of Public Health England computer software. In units of mGy, the median and range of ESAK per examination were found to be 10.8 (3.6–26.2), 7.0 (0.2–32.3), and 24.3 (9.0–32.0) in Hospitals A, B, and C, respectively. The overall mean and range of staff doses (in µGy) were found to be 310 (4.0–1750) per procedure. With the exception of hospital C, the present evaluations of radiation dose have been found to be similar to those of previously published research. The wide range of patient and staff doses illustrate the need for radiation dose optimisation. © 2020
URI
http://hdl.handle.net/11615/70450
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap