Investigation of attenuation correction in SPECT using textural features, Monte Carlo simulations, and computational anthropomorphic models

Thumbnail
Autor
Spirou, S. V.; Papadimitroulas, P.; Liakou, P.; Georgoulias, P.; Loudos, G.
Fecha
2015
DOI
10.1097/mnm.0000000000000345
Materia
attenuation correction
computational anthropomorphic model
GATE Monte
Carlo toolkit
single photon emission computed tomography
textural
features
XCAT
MYOCARDIAL-PERFUSION SPECT
JOINT POSITION STATEMENT
CT TEXTURE
CARDIAC SPECT
CANCER HETEROGENEITY
TUMOR HETEROGENEITY
NUCLEAR-CARDIOLOGY
AMERICAN-SOCIETY
SURVIVAL
CHEMOTHERAPY
Radiology, Nuclear Medicine & Medical Imaging
Mostrar el registro completo del ítem
Resumen
PurposeTo present and evaluate a new methodology to investigate the effect of attenuation correction (AC) in single-photon emission computed tomography (SPECT) using textural features analysis, Monte Carlo techniques, and a computational anthropomorphic model.Materials and methodsThe GATE Monte Carlo toolkit was used to simulate SPECT experiments using the XCAT computational anthropomorphic model, filled with a realistic biodistribution of Tc-99m-N-DBODC. The simulated gamma camera was the Siemens ECAM Dual-Head, equipped with a parallel hole lead collimator, with an image resolution of 3.54x3.54mm(2). Thirty-six equispaced camera positions, spanning a full 360 degrees arc, were simulated. Projections were calculated after applying a 20% energy window or after eliminating all scattered photons. The activity of the radioisotope was reconstructed using the MLEM algorithm. Photon attenuation was accounted for by calculating the radiological pathlength in a perpendicular line from the center of each voxel to the gamma camera. Twenty-two textural features were calculated on each slice, with and without AC, using 16 and 64 gray levels. A mask was used to identify only those pixels that belonged to each organ.ResultsTwelve of the 22 features showed almost no dependence on AC, irrespective of the organ involved. In both the heart and the liver, the mean and SD were the features most affected by AC. In the liver, six features were affected by AC only on some slices. Depending on the slice, skewness decreased by 22-34% with AC, kurtosis by 35-50%, long-run emphasis mean by 71-91%, and long-run emphasis range by 62-95%. In contrast, gray-level non-uniformity mean increased by 78-218% compared with the value without AC and run percentage mean by 51-159%. These results were not affected by the number of gray levels (16 vs. 64) or the data used for reconstruction: with the energy window or without scattered photons.ConclusionThe mean and SD were the main features affected by AC. In the heart, no other feature was affected. In the liver, other features were affected, but the effect was slice dependent. The number of gray levels did not affect the results. Copyright (C) 2015 Wolters Kluwer Health, Inc. All rights reserved.
URI
http://hdl.handle.net/11615/33302
Colecciones
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro
Help Contact
DepositionAboutHelpContacto
Choose LanguageTodo DSpace
EnglishΕλληνικά
htmlmap