The role of spectral response of photosensors in daylight responsive systems

Thumbnail
Συγγραφέας
Doulos, L.; Tsangrassoulis, A.; Topalis, F. V.
Ημερομηνία
2008
DOI
10.1016/j.enbuild.2007.04.010
Λέξη-κλειδί
daylight
photosensor
spectral response
AEROSOL OPTICAL DEPTH
DIMMING SYSTEM
SMALL OFFICE
PHOTOELECTRIC
CONTROL
LIGHTING SYSTEMS
PERFORMANCE
IRRADIANCE
ATHENS
GREECE
MODEL
Construction & Building Technology
Energy & Fuels
Engineering, Civil
Εμφάνιση Μεταδεδομένων
Επιτομή
Lighting control technologies using photosensors have a great potential for energy savings in areas with high levels of daylight. Although the proper application of these controls can exploit this potential, unfortunately, it has been accomplished in a small percentage of new projects. One reason is the difficulty in justification of energy savings, which in turn, is directly linked with the simulation of the behaviour of these lighting controls. The core of these systems is the photosensor, which adjusts the electric light output in proportion to the amount of the daylight that detects, using its spatial and spectral response. The aim of this study is to quantify the impact of photosensor spectral response on its illuminance values, by taking into account various daylight spectra as these are modified due to various types of coloured glazing. Five commercial photosensors were selected and their spectral response was measured. In addition, spectral transmittance of 16 commercial types of glazing was measured as well. Using these data, a set of simulations were performed using three colour channels in a typical office room and the relative differences in illuminance - and thus energy savings - among the photosensors are presented. The results show that differences are significant ranging from 36 to 118%, a fact that can affect the estimated payback period of a lighting control. system. (c) 2007 Elsevier B.V. All rights reserved.
URI
http://hdl.handle.net/11615/27200
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Πλοήγηση

Όλο το DSpaceΚοινότητες & ΣυλλογέςΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιάΑυτή η συλλογήΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιά

Ο λογαριασμός μου

ΣύνδεσηΕγγραφή (MyDSpace)
Πληροφορίες-Επικοινωνία
ΑπόθεσηΣχετικά μεΒοήθειαΕπικοινωνήστε μαζί μας
Επιλογή ΓλώσσαςΌλο το DSpace
EnglishΕλληνικά
htmlmap