Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts

Thumbnail
Auteur
Doulos, L.; Tsangrassoulis, A.; Topalis, F.
Date
2008
DOI
10.1016/j.enbuild.2007.01.019
Sujet
daylight
dimmable electronic ballast
energy savings
photosensor
LIGHTING CONTROLS
SMALL OFFICE
PERFORMANCE
Construction & Building Technology
Energy & Fuels
Engineering, Civil
Afficher la notice complète
Résumé
The application of lighting control technologies with photosensors has led to an increase in public interest. Although these technologies have been promoted during the last years their successful use in buildings has been accomplished in a small percentage of new projects. One reason is the difficulty in quantifying the energy savings and thus the subsequent payback period. Daylight responsive dimming systems consist of three basic components: photosensor, controller, and dimming unit. Electronic dimming ballast (EDB) is one substantial component of these lighting control systems which can adjust the light output due to the transferred signal from the photosensor and lighting controller. The aim of this study is to quantify energy savings among different EDBs. Eighteen commercial EDBs were selected and various sets of electrical and illuminance measurements were taken for different dimming levels, in order to develop polynomial functions between light output and consumed power. Using the measured data, a set of simulations were performed for a photosensor with an ideal cosine spatial sensitivity distribution installed in a typical office room using two control algorithms, closed loop and integral reset, trying to quantify the relative differences in energy savings. (c) 2007 Elsevier B.V. All fights reserved.
URI
http://hdl.handle.net/11615/27199
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19743]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap